ABS Sensor HH-TS1007
HEHUA NO: TS1007
OEM NO:
4410329000
504013848
1400071
801543
APPLICATION:DAF LF 45,LF 55
2 wire Hall effect ABS sensor
Connecting the lab scope
In this article the 2 wire Hall effect ABS sensor is measured. Instructions are shown on how to measure a 3 wire Hall effect ABS sensor so the 3 wire Hall effect ABS sensor can be measured as well. Signal patterns and diagnostic information for the 3 wire Hall effect ABS sensor can be read on the Hall effect crankshaft sensor page because they are similar.
Connecting to a 2 wire Hall effect ABS sensor
Correct functioning of the 2 wire Hall effect ABS sensor can be checked by measuring the following signal voltages:
Channel Probe Voltage Range
1 Red probe Sensor output signal 2 V
Black probe Ground at battery
2 Yellow probe Positive side of sensor power supply 20 V
Black probe Ground at battery
Measuring on a working 2 wire Hall effect ABS sensor
The lab scope is connected to the 2 wire Hall effect ABS sensor via a Measure lead TP-C1812B and Back Probe TP-BP85. The lab scope is set to normal scope mode with the trigger-timeout at infinite. When a one-shot measurement is started with these settings, the measurement is performed when the wheel is turned (by hand).
Connecting to a 3 wire Hall effect ABS sensor
Correct functioning of the 3 wire Hall effect ABS sensor can be checked by measuring the following signal voltages, see figure 5:
Channel Probe Voltage Range
1 Red probe Sensor output signal 20 V
Black probe Ground on battery
2 Yellow probe Positive side of sensor power supply 20 V
Black probe Negative side of sensor power supply
The lab scope is connected to the 3 wire Hall effect ABS sensor via a Measure lead TP-C1812B and Back Probe TP-BP85. The lab scope is set to normal scope mode with the trigger-timeout at infinite. When a one-shot measurement is started with these settings, the measurement is performed when the wheel is turned (by hand).